FreightUtils.com
UN1202

GAS OIL or DIESEL FUEL or HEATING OIL, LIGHT (flash-point not more than 60 °C)

Class 3Flammable LiquidsPacking Group III3 variants
UN 1202 has 3 classification variants in ADR 2025 — different hazard divisions or descriptions for the same UN number. Each variant may have different transport requirements.
Variant 1 of 3

GAS OIL or DIESEL FUEL or HEATING OIL, LIGHT (flash-point not more than 60 °C)

Hazard Class
3
Flammable Liquids
Classification Code
F1
Packing Group
III
Low danger
Hazard ID No.
30
Kemler code
Transport Category
3
For 1,000-point rule
Tunnel Code
(D/E)
Tunnel restriction
Hazard Labels Required
Label 3

These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.

Special Provisions
SP 640KSP 664

Refer to ADR 2025 Chapter 3.3 for full text of each provision.

Quantity Limits & Transport
Limited Quantity
5 L
Max per inner package for LQ relief
Excepted Quantity
E1
EQ code for excepted quantity relief
Transport Category
3
0=highest, 4=lowest restriction
Tunnel Restriction
(D/E)
Code governing tunnel passage
Variant 2 of 3

DIESEL FUEL complying with standard EN 590:2013 + A1:2017 or GAS OIL or HEATING OIL, LIGHT with a flash-point as specified in EN 590:2013 + A1:2017

Hazard Class
3
Flammable Liquids
Classification Code
F1
Packing Group
III
Low danger
Hazard ID No.
30
Kemler code
Transport Category
3
For 1,000-point rule
Tunnel Code
(D/E)
Tunnel restriction
Hazard Labels Required
Label 3

These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.

Special Provisions
SP 640LSP 664

Refer to ADR 2025 Chapter 3.3 for full text of each provision.

Quantity Limits & Transport
Limited Quantity
5 L
Max per inner package for LQ relief
Excepted Quantity
E1
EQ code for excepted quantity relief
Transport Category
3
0=highest, 4=lowest restriction
Tunnel Restriction
(D/E)
Code governing tunnel passage
Variant 3 of 3

GAS OIL or DIESEL FUEL or HEATING OIL, LIGHT (flash-point more than 60 °C and not more than 100 °C)

Hazard Class
3
Flammable Liquids
Classification Code
F1
Packing Group
III
Low danger
Hazard ID No.
30
Kemler code
Transport Category
3
For 1,000-point rule
Tunnel Code
(D/E)
Tunnel restriction
Hazard Labels Required
Label 3

These labels must be displayed on packages and vehicle placards in accordance with ADR 2025.

Special Provisions
SP 640MSP 664

Refer to ADR 2025 Chapter 3.3 for full text of each provision.

Quantity Limits & Transport
Limited Quantity
5 L
Max per inner package for LQ relief
Excepted Quantity
E1
EQ code for excepted quantity relief
Transport Category
3
0=highest, 4=lowest restriction
Tunnel Restriction
(D/E)
Code governing tunnel passage
Check if UN 1202 qualifies for 1.1.3.6 exemption
Calculate small load points and check exemption thresholds
Open calculator →

Other Flammable Liquids (Class 3)

UN 1088
ACETAL
UN 1089
ACETALDEHYDE
UN 1090
ACETONE
UN 1091
ACETONE OILS
UN 1093
ACRYLONITRILE, STABILIZED
Use this data programmatically
GET /api/adr?un=1202
View API Docs →
📅Data: UNECE ADR 2025, licensed from Labeline.com. Last verified April 2026

ADR reference data only. Classification is the consignor's legal responsibility. Consult a DGSA for compliance decisions.

Stay updated
ADR 2027 changes, new tools, and freight industry updates. No spam, unsubscribe anytime.
Related Tools
ADR 1.1.3.6 Exemption Calculator LQ/EQ Checker ADR Dangerous Goods Lookup

Found an error? Let us know → contact@freightutils.com